The relationship between ablation range and ablation energy in papillary thyroid microcarcinoma: a comparison between microwave ablation and laser ablation

乳头状甲状腺微癌消融范围与消融能量的关系:微波消融与激光消融的比较

阅读:1

Abstract

OBJECTIVES: To study the relationship between the ablation range and applied energy of laser ablation (LA) and microwave ablation (MWA) in papillary thyroid microcarcinoma (PTMC). METHODS: A total of 201 PTMC patients were treated with LA (n = 102) or MWA (n = 99) with single-applicator fixed ablation. The ablation range was determined by contrast-enhanced ultrasound. The ratios of ablation volume, longitudinal diameter, and orthogonal diameter to ablation energy (R(AV/E), R(AL/E), R(AO/E)) were analyzed and compared between MWA and LA. The effects of PTMC characteristics and Hashimoto's thyroiditis (HT) on ablation efficiency were evaluated by linear regression. RESULTS: The R(AV/E) was 0.72 (0.65-0.84) mm(3)/J for MWA and 0.48 (0.39-0.54) mm(3)/J for LA. HT was significantly correlated with R(AV/E) of LA (coefficient =  - 0.367, p < 0.0001). R(AL/E) did not differ significantly between MWA and LA (MWA 0.026 mm/J, LA 0.025 mm/J; p = 0.957). However, MWA had a greater R(AO/E) than LA (MWA 0.014 mm/J, LA 0.012 mm/J; p < 0.0001). The plateau values of MWA and LA on the ablation orthogonal diameter were 10.7 mm and 8.69 mm, respectively. CONCLUSIONS: MWA showed a higher R(AV/E) than LA. More intuitively, MWA had a better ablation performance than LA on the orthogonal axis rather than the longitudinal axis. Theoretically, MWA and LA could achieve complete ablation of ≤ 6.70 mm and ≤ 4.69 mm PTMC separately by single-applicator fixed ablation considering a unilateral 2-mm safe margin. HT had a negative effect on LA but not on MWA. CLINICAL RELEVANCE STATEMENT: This study establishes strong connections between ablation energy and ablation range in papillary thyroid microcarcinoma (PTMC) in vivo, possibly contributing to the supplementation of the PTMC Ablation Consensus or Guidelines and providing a scientific basis for choosing clinical ablation parameters in PTMC. KEY POINTS: • Both microwave ablation (MWA) and laser ablation (LA) have excellent performance on the ablation longitudinal axis (easily exceeding 10 mm) for papillary thyroid microcarcinoma (PTMC). • MWA performed much better than LA on the ablation orthogonal axis. • MWA and LA are expected to achieve complete ablation of ≤ 6.70 mm and ≤ 4.69 mm PTMC separately by single-applicator fixed ablation considering a unilateral 2-mm safe margin.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。