MR 4D flow-derived left atrial acceleration factor for differentiating advanced left ventricular diastolic dysfunction

磁共振4D血流衍生的左心房加速因子用于鉴别晚期左心室舒张功能障碍

阅读:1

Abstract

OBJECTIVES: The magnetic resonance (MR) 4D flow imaging-derived left atrial (LA) acceleration factor α was recently introduced as a means to non-invasively estimate LA pressure. We aimed to investigate the association of α with the severity of left ventricular (LV) diastolic dysfunction using echocardiography as the reference method. METHODS: Echocardiographic assessment of LV diastolic function and 3-T cardiac MR 4D flow imaging were prospectively performed in 94 subjects (44 male/50 female; mean age, 62 ± 12 years). LA early diastolic peak outflow velocity (v(E)), systolic peak inflow velocity (v(S)), and early diastolic peak inflow velocity (v(D)) were evaluated from 4D flow data. α was calculated from α = v(E) / [(v(S) + v(D)) / 2]. Mean parameter values were compared by t-test; diagnostic performance of α in predicting diastolic (dys)function was investigated by receiver operating characteristic curve analysis. RESULTS: Mean α values were 1.17 ± 0.14, 1.20 ± 0.08, 1.33 ± 0.15, 1.77 ± 0.18, and 2.79 ± 0.69 for grade 0 (n = 51), indeterminate (n = 9), grade I (n = 13), grade II (n = 13), and grade III (n = 8) LV diastolic (dys)function, respectively. α differed between subjects with non-advanced (grade < II) and advanced (grade ≥ II) diastolic dysfunction (1.20 ± 0.15 vs. 2.16 ± 0.66, p < 0.001). The area under the curve (AUC) for detection of advanced diastolic dysfunction was 0.998 (95% CI: 0.958-1.000), yielding sensitivity of 100% (95% CI: 84-100%) and specificity of 99% (95% CI: 93-100%) at cut-off α ≥ 1.58. The AUC for differentiating grade III diastolic dysfunction was also 0.998 (95% CI: 0.976-1.000) at cut-off α ≥ 2.14. CONCLUSION: The 4D flow-derived LA acceleration factor α allows grade II and grade III diastolic dysfunction to be distinguished from non-advanced grades as well as from each other. CLINICAL RELEVANCE STATEMENT: As a single continuous parameter, the 4D flow-derived LA acceleration factor α shows potential to simplify the multi-parametric imaging algorithm for diagnosis of advanced LV diastolic dysfunction, thereby identifying patients at increased risk for cardiovascular events. KEY POINTS: • Detection of advanced diastolic dysfunction is typically performed using a complex, multi-parametric approach. • The 4D flow-derived left atrial acceleration factor α alone allows accurate detection of advanced left ventricular diastolic dysfunction. • As a single continuous parameter, the left atrial acceleration factor α could simplify the diagnosis of advanced diastolic dysfunction.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。