Detection and size measurements of kidney stones on virtual non-contrast reconstructions derived from dual-layer computed tomography in an ex vivo phantom setup

在离体模型装置中,利用双层计算机断层扫描生成的虚拟非对比重建图像,检测和测量肾结石的大小。

阅读:2

Abstract

OBJECTIVES: To systematically investigate the usability of virtual non-contrast reconstructions (VNC) derived from dual-layer CT (DLCT) for detection and size measurements of kidney stones with regards to different degrees of surrounding iodine-induced attenuation and radiation dose. METHODS: Ninety-two kidney stones of varying size (3-14 mm) and composition were placed in a phantom filled with different contrast media/water mixtures exhibiting specific iodine-induced attenuation (0-1500 HU). DLCT-scans were acquired using CTDI(vol) of 2 mGy and 10 mGy. Conventional images (CI) and VNC(0H-1500HU) were reconstructed. Reference stone size was determined using a digital caliper (Man-M). Visibility and stone size were assessed. Statistical analysis was performed using the McNemar test, Wilcoxon test, and the coefficient of determination. RESULTS: All stones were visible on CI(0HU) and VNC(200HU). Starting at VNC(400 HU), the detection rate decreased with increasing HU and was significantly lower as compared to CI(0HU) on VNC(≥ 600HU) (100.0 vs. 94.0%, p < 0.05). The overall detection rate was higher using 10 mGy as compared to 2 mGy protocol (87.9 vs. 81.8%; p < 0.001). Stone size was significantly overestimated on all VNC compared to Man-M (7.0 ± 3.5 vs. 6.6 ± 2.8 mm, p < 0.001). Again, the 10 mGy protocol tended to show a better correlation with Man-M as compared to 2 mGy protocol (R(2) = 0.39-0.68 vs. R(2) = 0.31-0.57). CONCLUSIONS: Detection and size measurements of kidney stones surrounded by contrast media on VNC are feasible. The detection rate of kidney stones decreases with increasing iodine-induced attenuation and with decreasing radiation dose as well as stone size, while remaining comparable to CI(0HU) on VNC (≤ 400 HU). KEY POINTS: • The detection rate of kidney stones on VNC depends on the surrounding iodine-induced attenuation, the used radiation dose, and the stone size. • The detection rate of kidney stones on VNC decreases with greater iodine-induced attenuation and with lower radiation dose, particularly in small stones. • The visibility of kidney stones on VNC (≤ 400 HU) remains comparable to true-non-contrast scans even when using a low-dose technique.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。