Validation of a semi-automatic method to measure total liver volumes in polycystic liver disease on computed tomography - high speed and accuracy

利用计算机断层扫描技术验证一种测量多囊肝病患者肝脏总体积的半自动方法——快速准确

阅读:1

Abstract

OBJECTIVES: Polycystic liver disease (PLD) is characterized by growth of hepatic cysts, causing hepatomegaly. Disease severity is determined using total liver volume (TLV), which can be measured from computed tomography (CT). The gold standard is manual segmentation which is time-consuming and requires expert knowledge of the anatomy. This study aims to validate the commercially available semi-automatic MMWP (Multimodality Workplace) Volume tool for CT scans of PLD patients. METHODS: We included adult patients with one (n = 60) or two (n = 46) abdominal CT scans. Semi-automatic contouring was compared with manual segmentation, using comparison of observed volumes (cross-sectional) and growth (longitudinal), correlation coefficients (CC), and Bland-Altman analyses with bias and precision, defined as the mean difference and SD from this difference. Inter- and intra-reader variability were assessed using coefficients of variation (CV) and we assessed the time to perform both procedures. RESULTS: Median TLV was 5292.2 mL (IQR 3141.4-7862.2 mL) at baseline. Cross-sectional analysis showed high correlation and low bias and precision between both methods (CC 0.998, bias 1.62%, precision 2.75%). Absolute volumes were slightly higher for semi-automatic segmentation (manual 5292.2 (3141.4-7862.2) versus semi-automatic 5432.8 (3071.9-7960.2) mL, difference 2.7%, p < 0.001). Longitudinal analysis demonstrated that semi-automatic segmentation accurately measures liver growth (CC 0.908, bias 0.23%, precision 4.04%). Inter- and intra-reader variability were small (2.19% and 0.66%) and comparable to manual segmentation (1.21% and 0.63%) (p = 0.26 and p = 0.37). Semi-automatic segmentation was faster than manual tracing (19 min versus 50 min, p = 0.009). CONCLUSIONS: Semi-automatic liver segmentation is a fast and accurate method to determine TLV and liver growth in PLD patients. KEY POINTS: • Semi-automatic liver segmentation using the commercially available MMWP volume tool accurately determines total liver volume as well as liver growth over time in polycystic liver disease patients. • This method is considerably faster than manual segmentation through the use of Hounsfield unit settings. • We used a real-life CT set for the validation and showed that the semi-automatic tool measures accurately regardless of contrast used for the CT scan or not, presence of polycystic kidneys, liver volume, and previous invasive treatment for polycystic liver disease.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。