Density and morphology of coronary artery calcium for the prediction of cardiovascular events: insights from the Framingham Heart Study

冠状动脉钙化的密度和形态对心血管事件的预测:来自弗雷明汉心脏研究的启示

阅读:1

Abstract

OBJECTIVES: To investigate the association between directly measured density and morphology of coronary artery calcium (CAC) with cardiovascular disease (CVD) events, using computed tomography (CT). METHODS: Framingham Heart Study (FHS) participants with CAC in noncontrast cardiac CT (2002-2005) were included and followed until 2016. Participants with known CVD or uninterpretable CT scans were excluded. We assessed and correlated (Spearman) CAC density, CAC volume, and the number of calcified segments. Moreover, we counted morphology features including shape (cylindrical, spherical, semi-tubular, and spotty), location (bifurcation, facing pericardium, or facing myocardium), and boundary regularity. In multivariate Cox regression analyses, we associated all CAC characteristics with CVD events (CVD-death, myocardial infarction, stroke). RESULTS: Among 1330 included participants (57.8 ± 11.7 years; 63% male), 73 (5.5%) experienced CVD events in a median follow-up of 9.1 (7.8-10.1) years. CAC density correlated strongly with CAC volume (Spearman's ρ = 0.75; p < 0.001) and lower number of calcified segments (ρ = - 0.86; p < 0.001; controlled for CAC volume). In the survival analysis, CAC density was associated with CVD events independent of Framingham risk score (HR (per SD) = 2.09; 95%CI, 1.30-3.34; p = 0.002) but not after adjustment for CAC volume (p = 0.648). The extent of spherically shaped and pericardially sided calcifications was associated with fewer CVD events accounting for the number of calcified segments (HR (per count) = 0.55; 95%CI, 0.31-0.98; p = 0.042 and HR = 0.66; 95%CI, 0.45-0.98; p = 0.039, respectively). CONCLUSIONS: Directly measured CAC density does not predict CVD events due to the strong correlation with CAC volume. The spherical shape and pericardial-sided location of CAC are associated with fewer CVD events and may represent morphological features related to stable coronary plaques. KEY POINTS: • Coronary calcium density may not be independently associated with cardiovascular events. • Coronary calcium density correlates strongly with calcium volume. • Spherical shape and pericardial-sided location of CAC are associated with fewer CVD events.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。