Subtraction CT angiography improves evaluation of significant coronary artery disease in patients with severe calcifications or stents-the C-Sub 320 multicenter trial

减影CT血管造影可改善对伴有严重钙化或支架植入患者的显著冠状动脉疾病的评估——C-Sub 320多中心试验

阅读:1

Abstract

OBJECTIVES: Diagnostic accuracy of conventional coronary CT angiography (CCTA(conv)) may be compromised by blooming artifacts from calcifications or stents. Blooming artifacts may be reduced by subtraction coronary CT angiography (CCTA(sub)) in which non-contrast and contrast CT data sets are subtracted digitally. We tested whether CCTA(sub) in patients with severe coronary calcification or stents reduces the number of false-positive stenosis evaluations compared with CCTA(conv). METHODS: In this study, 180 symptomatic patients scheduled for invasive coronary angiography (ICA) were prospectively enrolled and CT scanned (2013-2016) at three international centers. CCTA(conv), and CCTA(sub) data sets were reconstructed. Target segments were defined as motion-free coronary segments with a suspected stenosis (> 50% of lumen) potentially due to blooming of either calcium or stents. Target segments were evaluated with respect to misregistration artifacts from the CCTA(sub) reconstruction process, in which case evaluation was omitted. CCTA(sub) and CCTA(conv) were compared with ICA. Primary outcome measure was the frequency of false positives by CCTA(conv) versus CCTA(sub) to identify > 50% coronary stenosis by ICA on a per-segment level. RESULTS: After exclusion of 76 patients, 104 (14% females) with mean age 67 years and median Agatston score 852 were included. There were 136 target segments with misregistration and 121 target segments without. Accuracy calculations in target segments without misregistration showed a reduction of the false positives from 72% [95% confidence interval (CI): 63-80%] in CCTA(conv) to 33% (CI:25-42%) in CCTA(sub), at the expense of 7% (CI:3-14%) false negatives in CCTA(sub). CONCLUSIONS: In severely calcified coronary arteries or stents, CCTA(sub) reduces the false-positive rate in well-aligned, calcified or stent segments suspected of significant stenosis on CCTA(conv). Nevertheless, misregistration artifacts are frequent in CCTA(sub). KEY POINTS: • A high calcium-score reduces the diagnostic accuracy in patients scanned with cardiac CT. • These patients would normally need an invasive angiogram for diagnosis. • In this prospective, multicenter study, subtraction CT, when evaluable, reduces false-positive stenosis evaluations. • Subtraction coronary CT angiography may, when evaluable, reduce excessive downstream testing.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。