Computer-aided detection in breast MRI: a systematic review and meta-analysis

计算机辅助乳腺MRI检测:系统评价和荟萃分析

阅读:2

Abstract

OBJECTIVES: To evaluate the additional value of computer-aided detection (CAD) in breast MRI by assessing radiologists' accuracy in discriminating benign from malignant breast lesions. METHODS: A literature search was performed with inclusion of relevant studies using a commercially available CAD system with automatic colour mapping. Two independent researchers assessed the quality of the studies. The accuracy of the radiologists' performance with and without CAD was presented as pooled sensitivity and specificity. RESULTS: Of 587 articles, 10 met the inclusion criteria, all of good methodological quality. Experienced radiologists reached comparable pooled sensitivity and specificity before and after using CAD (sensitivity: without CAD: 89%; 95% CI: 78-94%, with CAD: 89%; 95%CI: 81-94%) (specificity: without CAD: 86%; 95% CI: 79-91%, with CAD: 82%; 95% CI: 76-87%). For residents the pooled sensitivity increased from 72% (95% CI: 62-81%) without CAD to 89% (95% CI: 80-94%) with CAD, however, not significantly. Concerning specificity, the results were similar (without CAD: 79%; 95% CI: 69-86%, with CAD: 78%; 95% CI: 69-84%). CONCLUSIONS: CAD in breast MRI has little influence on the sensitivity and specificity of experienced radiologists and therefore their interpretation remains essential. However, residents or inexperienced radiologists seem to benefit from CAD concerning breast MRI evaluation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。