Determination of antibody induction by highly pathogenic porcine reproductive and respiratory syndrome virus (HP-PRRSV) vaccine: A comparison of two ELISA kits

高致病性猪繁殖与呼吸综合征病毒(HP-PRRSV)疫苗诱导抗体的测定:两种ELISA试剂盒的比较

阅读:1

Abstract

Two commercial porcine reproductive and respiratory syndrome virus (PRRSV) antibody ELISA kits (IDEXX and LSI) are currently in extensive use. To determine which kit is more suitable for the evaluation of HP-PRRSV vaccine efficacy, the two kits were used to test 546 serum samples. The agreement between the results was unsatisfactory, with a kappa statistic of 0.681 and a linear correlation coefficient of 0.665. In tests of samples from experimentally vaccinated and PRRSV-negative herds, IDEXX-ELISA identified antibody-positive conversion earlier and showed a higher specificity compared to LSI-ELISA. The serological profile obtained by neutralization testing was closer to that obtained by IDEXX-ELISA than by LSI-ELISA in the late immunization period. The findings reveal that IDEXX-ELISA is the more suitable for the evaluation of antibody response to HP-PRRSV vaccine and for guiding vaccination strategies.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。