Clinical study on the treatment of chronic heart failure with a novel D-shant atrium shunt device

新型D-shant心房分流装置治疗慢性心力衰竭的临床研究

阅读:1

Abstract

BACKGROUND: Atrial septal shunt devices might improve hospitalizations and also prognosis in heart failure with increased pulmonary pressures due to left heart diseases. In recent years, atrial shunt devices have been used for the treatment of chronic heart failure, but there remains a lack of clinical experience. This study aimed to analyse the therapeutic effect of a novel type of atrial shunt on chronic heart failure. METHODS AND RESULTS: From May 2020 to September 2020, six patients who were diagnosed with chronic heart failure and completed percutaneous D-shant atrium shunt device implantation in the Department of Cardiovascular Surgery, Union Hospital, were retrospectively included. The shunt location was evaluated by echocardiography and digital subtraction angiography. Heart function was evaluated by New York Heart Association functional class. Echocardiography was used to measure the diameter of the new chamber and ventricle, and to evaluate the degree of mitral and tricuspid regurgitation. Before operation and 6 months after operation, left atrial end-diastolic volume, right atrial end-diastolic volume, left ventricular end-diastolic volume, and right ventricular end-diastolic volume were measured by magnetic resonance imaging. Left ventricular ejection fractions and right ventricular ejection fractions were calculated. Haemodynamic indexes of right heart catheterization and clinical cardiac function indexes were collected and compared before and 6 months after shunt implantation. All six patients completed percutaneous shunt device implantation. Echocardiography and digital subtraction angiography showed that the shunt device was correctly positioned and unobstructed in all patients. Echocardiography revealed that the left ventricular diameter decreased significantly from 6.40 ± 0.57 mm to 5.03 ± 0.73 mm (P < 0.05). There was an obvious decrease in mitral regurgitation. Magnetic resonance imaging showed a reduction in the volume of the left ventricle (182.00 ± 27.02 mL vs. 125.75 ± 16.11 mL, P < 0.05). Cardiac catheter examination showed the mean left atrium pressure or pulmonary capillary wedge pressure decreased postoperatively (31.83 ± 11.55 vs. 18.00 ± 5.51 mmHg, P < 0.05). There was also obvious improvement in clinical indicators of cardiac function at 6 months after implantation. CONCLUSIONS: This novel D-shant atrium shunt device revealed maintained good function, no dislodgement and no paradoxical emboli. After implantation, functional mitral regurgitation in all patients with heart failure with reduced ejection fraction improved.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。