Temporary right ventricular circulatory support following right ventricular infarction: results of a groin-free approach

右心室梗死后临时性右心室循环支持:一种无需腹股沟入路的治疗结果

阅读:1

Abstract

AIMS: Acute right heart failure (RHF) is a severe complication of right ventricular infarction. The management of acute RHF poses a number of challenges, such as providing haemodynamic support. Temporary circulatory support (TCS) may be required upon failing medical therapy. The ProtekDuo® dual lumen cannula provides a minimally invasive option for (TCS) through a groin-free internal jugular vein approach. We present the largest patient series to date using the ProtekDuo® cannula as temporary right ventricular assist device (t-RVAD) in RHF after acute myocardial infarction (MI). METHODS AND RESULTS: From July 2016 to November 2019, 10 patients underwent t-RVAD implantation for RHF following acute MI. Transthoracic and transoesophageal echocardiography were performed in all patients to assess cardiac function, with a particular focus on RV function. Cumulative 30-day survival was 60%. Mean TAPSE was 6.4 ± 3.1 mm, mean fractional area change was 12.1 ± 4.2%, and mean right ventricular end diastolic area was 19.8 ± 2.7 cm(2) . Mean implantation time was 32.8 ± 8.3 min. Mean interval after first cardiac intervention was 4.6 ± 5.8 days. Mean t-RVAD time was 10.0 ± 7.4 days with a significant reduction in central venous pressure 19.3 ± 2.7 vs. 8.2 ± 2.6 mmHg, P < 0.001 and a significant increase in central venous saturation 52.8 ± 15.6 vs. 80.0 ± 6.0%, P < 0.001. Mean intensive care unit stay was 18.6 ± 12.2 days. Four patients were weaned from TCS. Two patients were bridged to a long-term paracorporeal RVAD. There were no t-RVAD associated complications. Causes of death (n = 4) were multiorgan failure, electromechanical dissociation, and haemorrhagic stroke. Mean follow-up time was 96.0 ± 107.6 days. No independent predictors of mortality were identified in univariate analysis. CONCLUSIONS: We show that groin-free, percutaneous implantation of the ProtekDuo® cannula is a feasible and safe tool for TCS in acute RHF post-MI. This approach provides the advantages of percutaneous implantation including complete mobilization and non-surgical bedside explantation, as well as the option for adding an oxygenator to the t-RVAD circuit.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。