Modelling the concentration of anti-SARS-CoV-2 immunoglobulin G in intravenous immunoglobulin product batches

模拟静脉注射免疫球蛋白产品批次中抗 SARS-CoV-2 免疫球蛋白 G 的浓度

阅读:9
作者:Sara Stinca, Thomas W Barnes, Peter Vogel, Wilfried Meyers, Johannes Schulte-Pelkum, Daniel Filchtinski, Laura Steller, Thomas Hauser, Sandro Manni, David F Gardiner, Sharon Popik, Nathan J Roth, Patrick Schuetz

Background

Plasma-derived intravenous immunoglobulin (IVIg) products contain a dynamic spectrum of immunoglobulin (Ig) G reactivities reflective of the donor population from which they are derived. We sought to model the concentration of anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG which could be expected in future plasma pool and final-product batches of CSL Behring's immunoglobulin product Privigen. Study design and

Conclusion

The work presented in this paper may have important implications for physicians and patients who use Privigen for indicated diseases.

Methods

Data was extracted from accessible databases, including the incidence of coronavirus disease 2019 and SARS-CoV-2 vaccination status, antibody titre in convalescent and vaccinated groups and antibody half-life. Together, these parameters were used to create an integrated mathematical model that could be used to predict anti-SARS-CoV-2 antibody levels in future IVIg preparations.

Results

We predict that anti-SARS-CoV-2 IgG concentration will peak in batches produced in mid-October 2021, containing levels in the vicinity of 190-fold that of the mean convalescent (unvaccinated) plasma concentration. An elevated concentration (approximately 35-fold convalescent plasma) is anticipated to be retained in batches produced well into 2022. Measurement of several Privigen batches using the Phadia™ EliA™ SARS-CoV-2-Sp1 IgG binding assay confirmed the early phase of this model.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。