Performance of nucleocapsid and spike-based SARS-CoV-2 serologic assays

进行基于核衣壳和刺突的 SARS-CoV-2 血清学检测

阅读:9
作者:Zahra Rikhtegaran Tehrani, Saman Saadat, Ebtehal Saleh, Xin Ouyang, Niel Constantine, Anthony L DeVico, Anthony D Harris, George K Lewis, Shyam Kottilil, Mohammad M Sajadi

Abstract

There is an urgent need for an accurate antibody test for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We have developed 3 ELISA methods, trimer spike IgA, trimer spike IgG, and nucleocapsid IgG, for detecting anti-SARS-CoV-2 antibodies. We evaluated their performance along with four commercial ELISAs, EDI™ Novel Coronavirus COVID-19 ELISA IgG and IgM, Euroimmun Anti-SARS-CoV-2 ELISA IgG and IgA, and one lateral flow assay, DPP® COVID-19 IgM/IgG System (Chembio). Both sensitivity and specificity were evaluated and the probable causes of false-positive reactions were determined. The assays were evaluated using 300 pre-epidemic samples and 100 PCR-confirmed COVID-19 samples. The sensitivities and specificities of the assays were as follows: 90%/100% (in-house trimer spike IgA), 90%/99.3% (in-house trimer spike IgG), 89%/98.3% (in-house nucleocapsid IgG), 73.7%/100% (EDI nucleocapsid IgM), 84.5%/95.1% (EDI nucleocapsid IgG), 95%/93.7% (Euroimmun S1 IgA), 82.8%/99.7% (Euroimmun S1 IgG), 82.0%/91.7% (Chembio nucleocapsid IgM), 92%/93.3% (Chembio nucleocapsid IgG). The presumed causes of false positive results from pre-epidemic samples in commercial and in-house assays were mixed. In some cases, assays lacked reproducibility. In other cases, reactivity was abrogated by competitive inhibition (spiking the sample with the same antigen that was used for coating ELISAs prior to performing the assay), suggesting positive reaction could be attributed to the presence of antibodies against these antigens. In other cases, reactivity was consistently detected but not abrogated by the spiking, suggesting positive reaction was not attributed to the presence of antibodies against these antigens. Overall, there was wide variability in assay performance using our samples, with in-house tests exhibiting the highest combined sensitivity and specificity. The causes of "false positivity" in pre-epidemic samples may be due to plasma antibodies apparently reacting with the corresponding antigen, or spurious reactivity may be directed against non-specific components in the assay system. Identification of these targets will be essential to improving assay performance.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。