Morphological and functional changes in spectral domain optical coherence tomography and microperimetry in macular microhole variants: spectral domain optical coherence tomography and microperimetry correlation

黄斑微孔变异型中光谱域光学相干断层扫描和微视野检查的形态学和功能变化:光谱域光学相干断层扫描和微视野检查的相关性

阅读:1

Abstract

PURPOSE: To evaluate the relationship between the morphology and retinal function of macular microhole (MMH) variants. MATERIALS AND METHODS: We evaluated 12 eyes of 11 patients with defects in the IS/OS junction of photoreceptor layer with SD-OCT. All patients underwent comprehensive ophthalmic examination including spectral domain optical coherence tomography (SD-OCT) and microperimetry. RESULTS: The mean logMAR visual acuity in the affected eye was 0.15 ± 0.17 (range 0.00-0.5). Mean horizontal diameter of the MMH was 163 ± 99 μm; the mean retinal sensitivity in the area corresponding to the MMH was 13.79 ± 4.6 dB. Negative correlation was found between the MMH diameter and the retinal sensitivity (r = -0.65, P = 0.02). Three morphological patterns of MMH variants were recognized on SD-OCT, which did not differ in retinal sensitivities. CONCLUSION: We described and classified the MMH variants and made an assessment on the physiological functions using microperimeter.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。