Noncontact Optical Measurement of Aqueous Humor Glucose Levels and Correlation with Serum Glucose Levels in Rabbit

兔房水葡萄糖水平的非接触式光学测量及其与血清葡萄糖水平的相关性

阅读:2

Abstract

The noninvasive measurement of serum glucose levels has been investigated for the monitoring of blood sugar control in diabetes. In our study, we aimed to develop a novel noncontact glucometer (NCGM) utilizing an optical approach to measure the intraocular aqueous humor glucose levels in the anterior chamber of rabbit eyes. The NCGM consists of a hybrid optical system that simultaneously measures near-infrared absorption and the polarized rotatory distribution of glucose molecules in the aqueous humor. In vitro optical measurements demonstrated that NCGM measurements had high precision and repeatability for different glucose levels, including 50 mg/dL (14.36%), 100 mg/dL (-4.05%), 200 mg/dL (-5.99%), 300 mg/dL (4.86%), 400 mg/dL (-2.84%), 500 mg/dL (-0.11%), and 600 mg/dL (4.48%). In the rabbit experiments, we found a high correlation between aqueous glucose levels and serum glucose levels, with a mean difference of 8 mg/dL. According to the testing results, the in vivo NCGM measurement of aqueous humor glucose levels also displayed a high correlation with serum glucose levels, with a mean difference of 29.2 mg/dL. In conclusion, aqueous humor glucose levels were accurately measured using the NCGM, and the results correlated with serum glucose levels.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。