Blood-based host biomarker diagnostics in active case finding for pulmonary tuberculosis: A diagnostic case-control study

基于血液的宿主生物标志物诊断在肺结核主动病例发现中的应用:一项诊断病例对照研究

阅读:2

Abstract

BACKGROUND: There is a need to identify scalable tuberculosis screening strategies among high burden populations. The WHO has identified a non-sputum-based triage test as a development priority. METHODS: We performed a diagnostic case-control study of point-of-care C-reactive protein (CRP) and Prototype-Xpert-MTB-Host-Response (Xpert-MTB-HR) assays in the context of a mass screening program for tuberculosis in two prisons in Brazil. All incarcerated individuals irrespective of symptoms were screened by sputum Xpert MTB/RIF and sputum culture. Among consecutive, Xpert MTB/RIF or culture-confirmed cases and Xpert MTB/RIF and culture-negative controls, CRP was quantified in serum by a point-of-care assay (iChroma-II) and a 3-gene expression score was quantified from whole blood using the Xpert-MTB-HR cartridge. We evaluated receiver operating characteristic area under the curve (AUC) and assessed specificity at 90% sensitivity and sensitivity at 70% specificity, consistent with WHO target product profile (TPP) benchmarks. FINDINGS: Two hundred controls (no TB) and 100 culture- or Xpert MTB/RIF-positive tuberculosis cases were included. Half of tuberculosis cases and 11% of controls reported any tuberculosis symptoms. AUC for CRP was 0·79 (95% CI: 0·73-0·84) and for Xpert-MTB-HR was 0·84 (95% CI: 0·79-0·89). At 90% sensitivity, Xpert-MTB-HR had significantly higher specificity (53·0%, 95% CI: 45·0-69·0%) than CRP (28·1%, 95% CI: 20·2-41·8%) (p = 0·003), both well below the TPP benchmark of 70%. Among individuals with medium or high sputum Xpert MTB/RIF semi-quantitative load, sensitivity (at 70% specificity) of CRP (90·3%, 95% CI: 74·2-98·0) and Xpert-MTB-HR (96·8%, 95% CI: 83·3-99·9%) was higher. INTERPRETATION: For active case finding in this high tuberculosis-burden setting, CRP and Xpert-MTB-HR did not meet TPP benchmarks for a triage test. However, Xpert-MTB-HR was highly sensitive in detecting individuals with medium or high sputum bacillary burden. FUNDING: National Institutes of Health (R01 AI130058 and R01 AI149620) and Brazilian National Council for Scientific and Technological Development (CNPq-404182/2019-4).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。