Results of a randomized phase III/IV trial comparing intermittent bolus versus continuous infusion of antihaemophilic factor (recombinant) in adults with severe or moderately severe haemophilia A undergoing major orthopaedic surgery

一项随机III/IV期试验的结果比较了在接受大型骨科手术的重度或中度重度A型血友病成人患者中,间歇性推注与持续输注抗血友病因子(重组)的疗效。

阅读:1

Abstract

INTRODUCTION: In patients with haemophilia A undergoing surgery, factor VIII (FVIII) replacement therapy by continuous infusion (CI) may offer an alternative to bolus infusion (BI). AIM: To compare the perioperative haemostatic efficacy and safety of antihaemophilic factor (recombinant) (ADVATE(®) ; Baxalta US Inc., a Takeda company, Lexington, MA, USA) CI or BI administration. METHODS: In this multicentre, phase III/IV, controlled study (NCT00357656), 60 previously treated adult patients with severe or moderately severe disease undergoing elective unilateral major orthopaedic surgery (knee replacement, n = 48; hip surgery, n = 4; other, n = 8) requiring drain placement were randomized to receive antihaemophilic factor (recombinant) CI (n = 29) or BI (n = 31) through postoperative day 7. Primary outcome measure was cumulative packed red blood cell (PRBC)/blood volume in the drainage fluid within 24 h after surgery, used to establish non-inferiority of CI to BI. RESULTS: CI:BI ratio of cumulative PRBC volume in the 24-h drainage fluid was 0.92 (p-value <.001 for non-inferiority; 95% confidence interval, 0.82-1.05). Total antihaemophilic factor (recombinant) dose per kg body weight received in the combined trans- and postoperative periods was similar with CI and BI to maintain targeted FVIII levels during/after surgery. Treatment-related adverse events (AEs) were reported in five patients treated by CI (eight events) and five treated by BI (six events), including two serious AEs in each arm. CONCLUSION: CI administration of antihaemophilic factor (recombinant) is a viable alternative to BI in patients with haemophilia A undergoing major orthopaedic surgery, providing comparable efficacy and safety.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。