Artificial Intelligence Enabled Fully Automated CMR Function Quantification for Optimized Risk Stratification in Patients Undergoing Transcatheter Aortic Valve Replacement

人工智能赋能全自动CMR功能定量分析,优化经导管主动脉瓣置换术患者的风险分层

阅读:2

Abstract

BACKGROUND: Cardiovascular magnetic resonance imaging is considered the reference standard for assessing cardiac morphology and function and has demonstrated prognostic utility in patients undergoing transcatheter aortic valve replacement (TAVR). Novel fully automated analyses may facilitate data analyses but have not yet been compared against conventional manual data acquisition in patients with severe aortic stenosis (AS). METHODS: Fully automated and manual biventricular assessments were performed in 139 AS patients scheduled for TAVR using commercially available software (suiteHEART®, Neosoft; QMass®, Medis Medical Imaging Systems). Volumetric assessment included left ventricular (LV) mass, LV/right ventricular (RV) end-diastolic/end-systolic volume, LV/RV stroke volume, and LV/RV ejection fraction (EF). Results of fully automated and manual analyses were compared. Regression analyses and receiver operator characteristics including area under the curve (AUC) calculation for prediction of the primary study endpoint cardiovascular (CV) death were performed. RESULTS: Fully automated and manual assessment of LVEF revealed similar prediction of CV mortality in univariable (manual: hazard ratio (HR) 0.970 (95% CI 0.943-0.997) p=0.032; automated: HR 0.967 (95% CI 0.939-0.995) p=0.022) and multivariable analyses (model 1: (including significant univariable parameters) manual: HR 0.968 (95% CI 0.938-0.999) p=0.043; automated: HR 0.963 [95% CI 0.933-0.995] p=0.024; model 2: (including CV risk factors) manual: HR 0.962 (95% CI 0.920-0.996) p=0.027; automated: HR 0.954 (95% CI 0.920-0.989) p=0.011). There were no differences in AUC (LVEF fully automated: 0.686; manual: 0.661; p=0.21). Absolute values of LV volumes differed significantly between automated and manual approaches (p < 0.001 for all). Fully automated quantification resulted in a time saving of 10 minutes per patient. CONCLUSION: Fully automated biventricular volumetric assessments enable efficient and equal risk prediction compared to conventional manual approaches. In addition to significant time saving, this may provide the tools for optimized clinical management and stratification of patients with severe AS undergoing TAVR.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。