Emission strength of airborne pathogens during toilet flushing

冲厕过程中空气传播病原体的排放强度

阅读:2

Abstract

The flushing of toilets generates contaminated aerosols, the transmission of which may cause the spread of disease, particularly in the immunocompromised or the elderly. This study investigated the emission strength of three types of airborne bacteria, namely Staphylococcus epidermidis, Escherichia coli, and Pseudomonas alcaligenes, during toilet flushing in a custom-built toilet under a controlled environment. Flushing was activated by a flushometer operated at two pressure levels, 400 kPa (high pressure [HP]) and 200 kPa (low pressure [LP]), and by a water cistern tank placed 95 cm (high tank [HT]) and 46 cm (low tank [LT]) above the toilet seat. The pathogens emitted by the first flush were calculated, with the correlations between airborne pathogen emissions and droplet concentration (HP, r=0.944, P<.001; LP, r=0.803, P<.001, HT, r=0.885, P<.05) and bacterial size (HP, r=-0.919, P<.001; LP, r=-0.936, P<.001; HT, r=-0.967, P<.05) in the different conditions then tested. The emission strength in the HP condition was statistically greater than that in the LP condition, whereas the cistern tank system produced less emissions than the flushometer system, and tank height was not found to be a sensitive parameter.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。