The effects of enhanced formaldehyde clearance in a gross anatomy laboratory by floor plan redesign and dissection table adjustment

通过重新设计平面图和调整解剖台来提高人体解剖实验室甲醛清除率的效果

阅读:1

Abstract

Formaldehyde has carcinogenic properties. It is associated with nasopharyngeal cancer and causes irritation of the eyes, nose, throat, and respiratory system. Formaldehyde exposure is a significant health concern for those participating in the gross anatomy laboratory, but no learning method can substitute cadaver dissection. We performed a formaldehyde level study in 2018, which found that most of the breathing zone (S-level) and environment (R-level) formaldehyde levels during laboratory sessions at the Faculty of Medicine Siriraj Hospital exceeded international ceiling standards. In the academic year 2019, we adapted the engineering rationale of the NIOSH hierarchy of controls to facilitate formaldehyde clearance by opening the dissection table covers and increasing the area per dissection table, then measured formaldehyde ceiling levels by formaldehyde detector tube with a gas-piston hand pump during (1) body wall, (2) upper limb, (3) head-neck, (4) thorax, (5) spinal cord removal, (6) lower limb, (7) abdomen, and (8) organs of special senses dissection sessions and comparing the results with the 2018 study. The perineum region data were excluded from analyses due to the laboratory closure in 2019 from the COVID-19 outbreak. There were statistically significant differences between the 2018 and 2019 S-levels (p < 0.001) and R-levels (p < 0.001). The mean S-level decreased by 64.18% from 1.34 ± 0.71 to 0.48 ± 0.26 ppm, and the mean R-level decreased by 70.18% from 0.57 ± 0.27 to 0.17 ± 0.09 ppm. The highest formaldehyde level in 2019 was the S-level in the body wall region (1.04 ± 0.3 ppm), followed by the S-level in the abdomen region (0.56 ± 0.08 ppm) and the spinal cord removal region (0.51 ± 0.29 ppm). All 2019 formaldehyde levels passed the OSHA 15-min STEL standard (2 ppm). The R-level in the special sense region (0.06 ± 0.02 ppm) passed the NIOSH 15-min ceiling limit (0.1 ppm). Three levels for 2019 were very close: the R-level in the head-neck region (0.11 ± 0.08 ppm), the abdomen region (0.11 ± 0.08), the body wall region (0.14 ± 0.12 ppm), and the S-level in the special sense region (0.12 ± 0.04 ppm). In summary, extensive analysis and removal of factors impeding formaldehyde clearance can improve the general ventilation system and achieve the OSHA 15-min STEL standard.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。