Augmentative Plating versus Exchange Intramedullary Nailing for the Treatment of Aseptic Non-Unions of the Femoral Shaft-A Biomechanical Study in a Sawbone(TM) Model

股骨干无菌性骨不连治疗中,加固钢板与髓内钉置换术的生物力学研究——基于Sawbone™模型

阅读:2

Abstract

BACKGROUND: Non-unions after intramedullary nailing of femoral shaft fractures are a significant problem. Treatment options such as augmenting with plates or exchange nailing have been proposed. The ideal treatment remains controversial. METHODS: Augmentative plating using a 4.5 mm LCP or a 3.2 mm LCP leaving the nail in situ was tested biomechanically and compared to exchange intramedullary nailing in a Sawbone(TM) model of a femoral shaft non-union. RESULTS: The difference of fracture gap motion in axial testing was small. In rotational testing, the exchange nail allowed for the largest amount of motion. The 4.5 mm augmentative plate was the most stable construct in all loading conditions. CONCLUSIONS: Augmentative plating using a 4.5 mm LCP plate while leaving the nail in situ is biomechanically superior to exchange intramedullary nailing. A small fragment 3.2 mm LCP is undersized and does not reduce fracture motion sufficiently in a femoral shaft non-union.