Role of a new age-adjusted D-dimer cutoff value for preoperative deep venous thrombosis exclusion in elderly patients with hip fractures

新的年龄校正D-二聚体临界值在老年髋部骨折患者术前排除深静脉血栓形成中的作用

阅读:2

Abstract

OBJECTIVE: This study aimed to describe the characteristics of plasma D-dimer level with increasing age and establish a new age-adjusted D-dimer cutoff value for excluding preoperative lower limb deep vein thrombosis (DVT) in elderly patients with hip fractures. METHODS: This was a retrospective study of elderly patients who presented with acute hip fracture in our institution between June 2016 and June 2019. All patients underwent D-dimer test and duplex ultrasound. Patients were divided into six 5-year-apart age groups. The optimal cutoff value for each group was calculated by using receiver operating characteristic (ROC) curves, whereby the new age-adjusted D-dimer cutoff value was determined. The sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) were calculated and compared when different D-dimer cutoff values were applied, i.e., conventional 0.5 mg/L, previously well-established age-adjusted cutoff value (age × 0.01 mg/L) and the new age-adjusted D-dimer cutoff value herein. RESULTS: There were 2759 patients included, 887 males and 1872 females, with an average age of 78 years. In total, 280 patients were diagnosed with preoperative DVT. The optimal cutoff values for the six age groups were 0.715 mg/L, 1.17 mg/L, 1.62 mg/L, 1.665 mg/L, 1.69 mg/L and 1.985 mg/L, respectively, and the calculated age-adjusted coefficient was 0.02 mg/L. With this new coefficient applied, the specificity was 61%, clearly higher than those for conventional threshold (0.5 mg/L, 37%) or previously established age-adjusted D-dimer threshold (age × 0.01 mg/L, 22%). In contrast, the sensitivity was lower than that (59% vs 85% or 77%) when D-dimer threshold of 0.5 mg/L or age-adjusted cutoff value (age × 0.01 mg/L) was used. The other indexes as PPV (15%, 11% and 12%) and NPV (93%, 93% and 94%) were comparable when three different D-dimer thresholds were applied. CONCLUSIONS: We developed a new age-adjusted D-dimer cutoff value (age × 0.02 mg/L) for a specified high-risk population of patients aged 65 years or older with hip fractures, and demonstrated the improved utility of the D-dimer test for exclusion of DVT. This formula can be considered for use in elderly hip fracture patients who meet the applicable standards as preoperative DVT screening, after its validity is confirmed by more well-evidenced studies.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。