Direct Measurement of Minimum Miscibility Pressure of Decane and CO(2) in Nanoconfined Channels

直接测量纳米限域通道中癸烷和CO(2)的最小混溶压力

阅读:1

Abstract

Determining gas and oil minimum miscibility pressure (MMP) plays a vital role in the enhanced oil recovery. Injecting gases above the MMP into oil reservoirs leads to a relatively high oil recovery ratio. For conventional reservoirs, the fluid bulk MMP is measured by lab techniques such as the rising bubble approach. However, for the increasingly important tight and shale reservoirs, oil is confined in nanoscale pores. Nanoscopic MMP remains largely unknown from experiments and relies heavily on theoretical predictions. To close this gap, we developed a nanofluidic device to determine the MMP down to 50 nm by measuring the fluorescence intensity change in a nanoconfined channel. CO(2) and decane are used as the working fluids, with 1% fluorescent dye for characterization. At the isothermal condition, the fluorescence intensity in decane reduces with the injecting CO(2) pressure increasing, and the maximum fluorescence intensity reduction at certain CO(2) pressure indicates the MMP being reached. We measured and compared CO(2) and decane MMP at the bulk scale (5 μm) and nanoscale (50 nm). The experimental results align well with literature data and theoretical predictions. Importantly, our nanofluidic approach provides a promising strategy to determine the nanoscopic fluid MMP and is readily applicable in assisting the enhanced tight/shale oil recovery.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。