Conclusions
Low-pressure endometrial suction devices provide tissue samples with acceptable RNA purity and quantity for gene expression studies. The expression of HOXA10 did not differ between endometrial sampling sites even in the presence of leiomyomas.
Objective
To compare ribonucleic acid (RNA) quantity and purity in tissue collected with different endometrial sampling
Results
The median weight of the samples was significantly larger when obtained with the low-pressure suction device than with the resectoscope loop (153 vs. 20 mg). The RNA yield was similar (suction curette, 1,625 ng/mg; resectoscope loop, 1,779 ng/mg). The A260-to-A280 ratio was satisfactory for 94.7 % of the samples, with no difference between the groups. The endometrial expression of HOXA10 was similar in areas overlying the leiomyoma compared with that in remote endometrial sites (2-ΔCt = 0.0224 vs. 0.0225). Conclusions: Low-pressure endometrial suction devices provide tissue samples with acceptable RNA purity and quantity for gene expression studies. The expression of HOXA10 did not differ between endometrial sampling sites even in the presence of leiomyomas.