Effects of different three-dimensional electrodes on epiretinal electrical stimulation by modeling analysis

通过建模分析研究不同三维电极对视网膜上电刺激的影响

阅读:1

Abstract

BACKGROUND: Epiretinal prostheses have been greatly successful in helping restore the vision of patients blinded by retinal degenerative diseases. The design of stimulating electrodes plays a crucial role in the performance of epiretinal prostheses. The objective of this study was to investigate, through computational modeling analysis, the effects on the excitation of retinal ganglion cells (RGCs) when different three-dimensional (3-D) electrodes were placed in the epiretinal space. METHODS: 3-D finite element models of retinal electrical stimulation were created in COMSOL using a platinum microelectrode, a vitreous body, multi-layered retinal tissue, and retinal pigment epithelium (RPE). Disk and non-planar electrodes with different 3-D structures were used in the epiretinal electrical stimulation. In addition, a multi-RGC model including ionic mechanisms was constructed in NEURON to study the excitability of RGCs in response to epiretinal electrical stimulation by different types of electrodes. Threshold current, threshold charge density, and the activated RGC area were the three key factors used to evaluate the stimulating electrode's performance. RESULTS: As the electrode-retina distance increased, both threshold current and threshold charge density showed an approximately linear relationship. Increasing the disk electrode's diameter resulted in an increase in threshold current and a decrease in threshold charge density. Non-planar electrodes evoked different activation responses in RGCs than the disk electrode. Concave electrodes produced superior stimulation localization and electrode safety while convex electrodes performed relatively poorly. CONCLUSIONS: Investigation of epiretinal electrical stimulation using different 3-D electrodes would further the optimization of electrode design and help improve the performance of epiretinal prostheses. The combination of finite element analysis in COMSOL and NEURON software provides an efficient way to evaluate the influences of various 3-D electrodes on epiretinal electrical stimulation. Non-planar electrodes had larger threshold currents than disk electrodes. Of the five types of electrodes, concave hemispherical electrodes may be the ideal option, considering their superior stimulation localization and electrode safety.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。