Bacterial Adherence Around Sutures of Different Material at Grafted Site: A Microbiological Analysis

不同材料缝合线周围细菌在移植部位的黏附情况:微生物学分析

阅读:1

Abstract

Closure of the surgical incision has been the primary function of sutures since their introduction. However, whatever the type, they are known to carry bacteria, which can be a source of infection. Five types of surgical sutures, Gut, Silk, Vicryl, PTFE, and Polyamide, were selected and tested on their ability to carry aerobic and anaerobic bacteria and were rated on the basis of forming colony-forming units (CFUs). Aerobic bacteria grown around gut sutures showed minimum CFUs (≈30 × 10(4)/suture). Though very less anaerobic bacteria growth was seen among all tested suture materials, it was maximum around Vicryl and polyamide sutures. Every suture material is capable, albeit not equally, of holding bacterial biofilm formation, which can be a source of surgical site infection.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。