Application of Video Laryngoscopy for Minimally Invasive Surfactant Therapy: A Retrospective Comparative Cohort Study

视频喉镜在微创表面活性剂治疗中的应用:一项回顾性比较队列研究

阅读:1

Abstract

Minimally invasive surfactant therapy (MIST) has emerged as a preferred method of surfactant delivery. Pioneers of this technique have described the use of direct laryngoscopy (DL) for MIST. With the increasing application of video laryngoscopy (VL) for neonatal airway management, it is speculated that MIST techniques can be adapted for use with VL. OBJECTIVE: To compare procedural success, operator ease of use, and complication of MIST using VL vs. MIST using DL. METHODS: This was a retrospective, observational cohort study conducted at a tertiary-level neonatal intensive care unit after obtaining ethical approval. We included neonates who received MIST between 1 October 2020 and 31 October 2022. Baseline demographic characteristics, along with procedural data, were collected. Primary outcome measures included the overall procedural success rate, the need for multiple attempts, and the total number of attempts. Secondary outcome measures included the occurrence of adverse events, the need for a second dose of surfactant, and the need for intubation within 7 days of the procedure. Means and SDs, independent t-tests, frequencies, and chi-square were used as appropriate. p-values < 0.05 were considered statistically significant. RESULTS: Of the 79 neonates included, 37 neonates received MIST via VL, while 42 received MIST via DL. The median gestational age was lower in the VL group at 29.0 weeks vs. 30.5 weeks (p = 0.011) in the DL group. The median birthweight in the VL group was 1260 g, IQR (1080, 1690), which was significantly lower than the DL group, which was 1575 g, IQR (1220, 2251), p = 0.028. Purpose-built catheter use was higher in the DL group. The overall procedural success was similar between groups. The need for multiple attempts was lower with VL in comparison to DL [4 (11%) vs. 13 (31%); p = 0.034)] at the univariate level but not significant at multivariate analysis (p = 0.131). Procedural complications, the need for a second dose of surfactant, the need for mechanical ventilation post-MIST, and operator ease of use were similar. User comments emphasized the value of VL in providing real-time visual information to confirm catheter placement and guide operators/trainees. CONCLUSION: Overall, in our cohort, despite VL being a more recently adapted technology used more in smaller, sicker, and more premature neonates, procedural success, complications, and operator ease of use for MIST using VL and DL were comparable. Our findings show the successful application of VL for MIST and suggest procedural advantages that might facilitate universal adoption.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。