Abstract

We report a highly sensitive and selective CNT-switch liquid biopsy platform that detects and quantifies protein biomarker expressions from circulating tumor cells in blood for early detection of metastatic breast cancer and its relapse. This platform first isolates and enriches more than 99% of tumor cells with an off-chip micro-size membrane filtration technique and then conducts on-chip detection of the membrane and internal protein biomarkers of the tumor cells with high sensitivity and selectivity. High sensitivity is achieved with complete association of the antibody-antigen-antibody (Ab-Ag-Ab) complex by precisely and rapidly assembling carbon nanotubes (CNTs) across two parallel electrodes via sequential DC electrophoresis and dielectrophoresis (DEP) deposition. Each bridged CNT acts as a switch that connects the electrodes and closes the circuit to generate an electrical signal. The high selectivity is achieved with a critical hydrodynamic shear rate that irreversibly removes non-target linkers of the aligned CNTs. At present, we are able to detect the protein biomarkers from 5 spiked breast cancer tumor cells of different types within 7.5 ml of human blood samples. This demonstrates the potential of this platform as an inexpensive and noninvasive alternative to MRI scans and tissue biopsies currently used to detect early metastatic breast cancer and its relapse.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。