Artificial Intelligence-Assisted Capsule Endoscopy Versus Conventional Capsule Endoscopy for Detection of Small Bowel Lesions: A Systematic Review and Meta-Analysis

人工智能辅助胶囊内镜与传统胶囊内镜在小肠病变检测中的比较:系统评价和荟萃分析

阅读:1

Abstract

BACKGROUND: Capsule endoscopy (CE) is a valuable tool used in the diagnosis of small intestinal lesions. The study aims to systematically review the literature and provide a meta-analysis of the diagnostic accuracy, specificity, sensitivity, and negative and positive predictive values of AI-assisted CE in the diagnosis of small bowel lesions in comparison to CE. METHODS: Literature searches were performed through PubMed, SCOPUS, and EMBASE to identify studies eligible for inclusion. All publications up to 24 November 2024 were included. Original articles (including observational studies and randomized control trials), systematic reviews, meta-analyses, and case series reporting outcomes on AI-assisted CE in the diagnosis of small bowel lesions were included. The extracted data were pooled, and a meta-analysis was performed for the appropriate variables, considering the clinical and methodological heterogeneity among the included studies. Comprehensive Meta-Analysis v4.0 (Biostat Inc.) was used for the analysis of the data. RESULTS: A total of 14 studies were included in the present study. The mean age of participants across the studies was 54.3 years (SD 17.7), with 55.4% men and 44.6% women. The pooled accuracy for conventional CE was 0.966 (95% CI: 0.925-0.988), whereas for AI-assisted CE, it was 0.9185 (95% CI: 0.9138-0.9233). Conventional CE exhibited a pooled sensitivity of 0.860 (95% CI: 0.786-0.934) compared with AI-assisted CE at 0.9239 (95% CI: 0.8648-0.9870). The positive predictive value for conventional CE was 0.982 (95% CI: 0.976-0.987), whereas AI-assisted CE had a PPV of 0.8928 (95% CI: 0.7554-0.999). The pooled specificity for conventional CE was 0.998 (95% CI: 0.996-0.999) compared with 0.5367 (95% CI: 0.5244-0.5492) for AI-assisted CE. Negative predictive values were higher in AI-assisted CE at 0.9425 (95% CI: 0.9389-0.9462) versus 0.760 (95% CI: 0.577-0.943) for conventional CE. CONCLUSION: AI-assisted CE displays superior diagnostic accuracy, sensitivity, and positive predictive values albeit the lower pooled specificity in comparison with conventional CE. Its use would ensure accurate detection of small bowel lesions and further enhance their management.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。