Double-balloon Trapping for Coil Embolization of Ruptured Internal Carotid Artery Aneurysm: A Novel Technique

双球囊阻滞术治疗破裂性颈内动脉瘤栓塞术:一种新技术

阅读:1

Abstract

INTRODUCTION: Endovascular treatment of complex ruptured aneurysms in the internal carotid (IC) artery is extremely challenging. Navigation of double-balloon catheters becomes all the more difficult in tortuous vessels. PATIENTS AND METHODS: A 57-year-old female with more than three times previously ruptured left IC artery aneurysm with subarachnoid hemorrhage had a left IC small aneurysm with a neck of 3.2 mm. Proximal and distal balloons were inflated in left IC artery in respect to the aneurysm, to prevent further rupture during navigation of the microcatheter and first coil. DISCUSSION: The technique uses two balloons placed proximal and distal to the ruptured aneurysm, to reduce further bleeding, just as the application of temporary clips, followed by inertion of coils rapidly to obliterate the aneurysm. CONCLUSION: It is a novel technique of double-balloon trapping of proximal and distal segment of IC artery with aneurysm coiling technique as an alternative to balloon-assisted coiling and stent-assisted coiling in patients with ruptured aneurysm.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。