Abstract
Transcorneal electrical stimulation (TES) is a promising treatment for several retinal degenerative diseases (RDDs). TES involves the application of a controlled electrical current to the anterior surface of the cornea, aimed at activating the retina and posterior ocular structures. Dawson-Trick-Litzkow (DTL) and ERG-JET electrodes are among the most widely used for TES. However, their continuous metallic surface design limits spatial resolution and the ability to perform selective ES. In this work, we present the development of a transcorneal electrical stimulation (TES) electrode that, unlike conventional electrodes, enables spatially selective TES. The proposed electrode design consists of an array of 20 independent microelectrodes distributed across the central and paracentral regions of the cornea. The fabrication process combines surface micromachining and flexible electronics technologies, employing only three structural materials: aluminum (Al), titanium (Ti), and polyimide (PI). This material selection is critical for achieving a simplified, reproducible, and low-cost fabrication process. The fabricated electrode was validated through electrical and electrochemical testing. The results show a relatively high electrical conductivity of Al/Ti structures, low electrochemical impedance values-ranging from 791 kΩ to 1.75 MΩ for the clinically relevant frequency range (11 to 30 Hz)-and a high charge storage capacity of 1437 mC/cm(2). The electrode capacity for electrical signal transmission was demonstrated through in vitro testing. Finally, the applicability of the TES electrode for electroretinogram (ERG) recording was evaluated by measuring its optical transmittance across the visible wavelength range.