Volumetric Pancreas Segmentation on Computed Tomography: Accuracy and Efficiency of a Convolutional Neural Network Versus Manual Segmentation in 3D Slicer in the Context of Interreader Variability of Expert Radiologists

基于计算机断层扫描的胰腺容积分割:在专家放射科医生阅片者间差异的背景下,卷积神经网络与3D Slicer中手动分割的准确性和效率比较

阅读:1

Abstract

PURPOSE: This study aimed to compare accuracy and efficiency of a convolutional neural network (CNN)-enhanced workflow for pancreas segmentation versus radiologists in the context of interreader reliability. METHODS: Volumetric pancreas segmentations on a data set of 294 portal venous computed tomographies were performed by 3 radiologists (R1, R2, and R3) and by a CNN. Convolutional neural network segmentations were reviewed and, if needed, corrected ("corrected CNN [c-CNN]" segmentations) by radiologists. Ground truth was obtained from radiologists' manual segmentations using simultaneous truth and performance level estimation algorithm. Interreader reliability and model's accuracy were evaluated with Dice-Sorenson coefficient (DSC) and Jaccard coefficient (JC). Equivalence was determined using a two 1-sided test. Convolutional neural network segmentations below the 25th percentile DSC were reviewed to evaluate segmentation errors. Time for manual segmentation and c-CNN was compared. RESULTS: Pancreas volumes from 3 sets of segmentations (manual, CNN, and c-CNN) were noninferior to simultaneous truth and performance level estimation-derived volumes [76.6 cm 3 (20.2 cm 3 ), P < 0.05]. Interreader reliability was high (mean [SD] DSC between R2-R1, 0.87 [0.04]; R3-R1, 0.90 [0.05]; R2-R3, 0.87 [0.04]). Convolutional neural network segmentations were highly accurate (DSC, 0.88 [0.05]; JC, 0.79 [0.07]) and required minimal-to-no corrections (c-CNN: DSC, 0.89 [0.04]; JC, 0.81 [0.06]; equivalence, P < 0.05). Undersegmentation (n = 47 [64%]) was common in the 73 CNN segmentations below 25th percentile DSC, but there were no major errors. Total inference time (minutes) for CNN was 1.2 (0.3). Average time (minutes) taken by radiologists for c-CNN (0.6 [0.97]) was substantially lower compared with manual segmentation (3.37 [1.47]; savings of 77.9%-87% [ P < 0.0001]). CONCLUSIONS: Convolutional neural network-enhanced workflow provides high accuracy and efficiency for volumetric pancreas segmentation on computed tomography.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。