Simplified meal announcement study (SMASH) using hybrid closed-loop insulin delivery in youth and young adults with type 1 diabetes: a randomised controlled two-centre crossover trial

一项针对 1 型糖尿病青少年和青年患者的简化膳食通知研究 (SMASH),采用混合闭环胰岛素输注系统:一项随机对照双中心交叉试验

阅读:1

Abstract

AIMS/HYPOTHESIS: The majority of hybrid closed-loop systems still require carbohydrate counting (CC) but the evidence for its justification remains limited. Here, we evaluated glucose control with simplified meal announcement (SMA) vs CC in youth and young adults with type 1 diabetes using the mylife CamAPS FX system. METHODS: We conducted a two-centre, randomised crossover, non-inferiority trial in two University Hospitals in Switzerland in 46 participants (aged 12-20 years) with type 1 diabetes using multiple daily injections (n=35), sensor-augmented pump (n=4) or hybrid closed-loop (n=7) therapy before enrolment. Participants underwent two 3 month periods with the mylife CamAPS FX system (YpsoPump, Dexcom G6) to compare SMA (individualised carbohydrate meal sizes) with CC, in a randomly assigned order using computer-generated sequences. The primary endpoint was the proportion of time glucose was in target range (3.9-10.0 mmol/l) with a non-inferiority margin of 5 percentage points. Secondary endpoints were other sensor glucose and insulin metrics, usability and safety endpoints. RESULTS: Forty-three participants (18 women and girls) completed the trial. In the intention-to-treat analysis, time in range (mean±SD) was 69.9±12.4% with SMA and 70.7±13.0% with CC (estimated mean difference -0.6 percentage points [95% CI -2.4, 1.1], demonstrating non-inferiority). Time <3.9 mmol/l (median [IQR] 1.8 [1.2-2.2]% vs 1.9 [1.6-2.5]%) and >10.0 mmol/l (28.2±12.6% vs 27.2±13.4%) was similar between periods. Total daily insulin dose was higher with SMA (54.0±14.7 U vs 51.7±12.1 U, p=0.037). Three participants experienced serious adverse events, none of which were intervention-related. CONCLUSIONS/INTERPRETATION: Glucose control using the CamAPS FX algorithm with SMA was non-inferior to its use with CC in youth and young adults with type 1 diabetes. TRIAL REGISTRATION: ClinicalTrials.gov NCT05481034. FUNDING: The study was supported by the Swiss Diabetes Foundation and by a YTCR grant from the Bangerter-Rhyner Foundation and the Swiss Academy of Medical Sciences. Dexcom and Ypsomed provided product support.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。