Electric Susceptibility at Partial Coverage of a Circular One-Side Access Capacitive Sensor with Rigid Polyurethane Foams

硬质聚氨酯泡沫对圆形单侧电容式传感器部分覆盖时的电场敏感性

阅读:1

Abstract

The capability of dielectric measurements was significantly increased with the development of capacitive one-side access physical sensors. Complete samples give no opportunity to study electric susceptibility at a partial coverage of the one-side access sensor's active area; therefore, partial samples are proposed. The electric susceptibility at the partial coverage of a circular one-side access sensor with cylinders and shells is investigated for polyurethane materials. The implementation of the relative partial susceptibility permitted us to transform the calculated susceptibility data to a common scale of 0.0-1.0 and to outline the main trends for PU materials. The partial susceptibility, relative partial susceptibility, and change rate of relative partial susceptibility exhibited dependence on the coverage coefficient of the sensor's active area. The overall character of the curves for the change rate of the relative partial susceptibility, characterised by slopes of lines and the ratio of the change rate in the centre and near the gap, corresponds with the character of the surface charge density distribution curves, calculated from mathematical models. The elaborated methods may be useful in the design and optimization of capacitive OSA sensors of other configurations of electrodes, independent of the particular technical solution.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。