Temporary self-expanding metallic stents for achalasia: a prospective study with a long-term follow-up

暂时性自膨式金属支架治疗贲门失弛症:一项前瞻性长期随访研究

阅读:2

Abstract

AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm (n = 30, group A), 25 mm (n = 30, group B) or 30 mm (n = 30, group C). Data on clinical symptoms, complications and treatment outcomes were collected, and follow-up was made at 6 mo and at 1, 3-5, 5-8, 8-10 and > 10 years, postoperatively. RESULTS: Stent placement was successful in all patients. Although chest pain occurrence was high, stent migration was less in group C than in groups A and B. The clinical remission rate at 5-8, 8-10 and > 10 years in group C was higher than that in the other two groups. The treatment failure rate was lower in group C (13%) than in groups A (53%) and B (27%). SEMSs in group C resulted in reduced dysphagia scores and lowered esophageal sphincter pressures, as well as normal levels of barium height and width during all the follow-up time periods. Conversely, these parameters increased over time in groups A and B. The primary patency in group C was longer than in groups A and B. CONCLUSION: A temporary SEMS with a diameter of 30 mm is associated with a superior long-term clinical efficacy in the treatment of achalasia compared with a SEMS with a diameter of 20 mm or 25 mm.