Administrative data underestimate acute ischemic stroke events and thrombolysis treatments: Data from a multicenter validation survey in Italy

行政数据低估了急性缺血性卒中事件和溶栓治疗:来自意大利一项多中心验证调查的数据

阅读:1

Abstract

BACKGROUND: Informing health systems and monitoring hospital performances using administrative data sets, mainly hospital discharge data coded according to International-Classification-Diseases-9edition-Clinical-Modifiers (ICD9-CM), is now commonplace in several countries, but the reliability of diagnostic coding of acute ischemic stroke in the routine practice is uncertain. This study aimed at estimating accuracy of ICD9-CM codes for the identification of acute ischemic stroke and the use of thrombolysis treatment comparing hospital discharge data with medical record review in all the six hospitals of the Florence Area, Italy, through 2015. METHODS: We reviewed the medical records of all the 3915 potential acute stroke events during 2015 across the six hospitals of the Florence Area, Italy. We then estimated sensitivity and Positive Predictive Value of ICD9-CM code-groups 433*1, 434*1 and thrombolysis code 99.10 against medical record review with clinical adjudication. For each false-positive case we obtained the actual diagnosis. For each false-negative case we obtained the primary and secondary ICD9-CM diagnoses. RESULTS: The medical record review identified 1273 acute ischemic stroke events. The hospital discharge records identified 898 among those (true-positive cases),but missed 375 events (false-negative cases), and identified 104 events that were not eventually confirmed as acute ischemic events (false-positive cases). Code-group specific Positive Predictive Value was 85.7% (95%CI,74.6-93.3) for 433*1 and 89.9% (95%CI, 87.8-91.7) for 434*1 codes. Thrombolysis treatment, as identified by ICD9-CM code 99.10, was only documented in 6.0% of acute ischemic stroke events, but was 13.6% in medical record review. CONCLUSIONS: Hospital discharge data were found to be fairly specific but insensitive in the reporting of acute ischemic stroke and thrombolysis, providing misleading indications about both quantity and quality of acute ischemic stroke hospital care. Efforts to improve coding accuracy should precede the use of hospital discharge data to measure hospital performances in acute ischemic stroke care.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。