Comparison between synchronized and non-synchronized ventilation and between guided and non-guided chest compressions during resuscitation in a pediatric animal model after asphyxial cardiac arrest

在窒息性心脏骤停后的儿科动物模型中,比较同步通气与非同步通气以及指导性胸外按压与非指导性胸外按压在复苏过程中的效果

阅读:1

Abstract

INTRODUCTION: There are no studies comparing synchronized and non-synchronized ventilation with bag-valve mask ventilation (BVMV) during cardiopulmonary resuscitation (CPR) in pediatric patients. The main aim is to compare between synchronized and non-synchronized BVMV with chest compressions (CC), and between guided and non-guided CC with a real-time feedback-device in a pediatric animal model of asphyxial cardiac arrest (CA). The secondary aim is to analyze the quality of CC during resuscitation. METHODS: 60 piglets were randomized for CPR into four groups: Group A: guided-CC and synchronized ventilation; Group B: guided-CC and non-synchronized ventilation; Group C: non-guided CC and synchronized ventilation; Group D: non-guided CC and non-synchronized ventilation. Return of spontaneous circulation (ROSC), hemodynamic and respiratory parameters, and quality of CC were compared between all groups. RESULTS: 60 piglets were included. Twenty-six (46.5%) achieved ROSC: A (46.7%), B (66.7%), C (26.7%) and D (33.3%). Survival rates were higher in group B than in groups A+C+D (66.7% vs 35.6%, p = 0.035). ROSC was higher with guided-CC (A+B 56.7% vs C+D 30%, p = 0.037). Piglets receiving non-synchronized ventilation did not show different rates of ROSC than synchronized ventilation (B+D 50% vs A+C 36.7%, p = 0.297). Non-synchronized groups showed lower arterial pCO2 after 3 minutes of CPR than synchronized groups: 57 vs 71 mmHg, p = 0.019. No differences were found in arterial pH and pO2, mean arterial pressure (MAP) or cerebral blood flow between groups. Chest compressions were shallower in surviving than in non-surviving piglets (4.7 vs 5.1 cm, p = 0.047). There was a negative correlation between time without CC and MAP (r = -0.35, p = 0.038). CONCLUSIONS: The group receiving non-synchronized ventilation and guided-CC obtained significantly higher ROSC rates than the other modalities of resuscitation. Guided-CC achieved higher ROSC rates than non-guided CC. Non-synchronized ventilation was associated with better ventilation parameters, with no differences in hemodynamics or cerebral flow.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。