Thyroid-optimized and thyroid-sparing radiotherapy in oral cavity and oropharyngeal carcinoma: A dosimetric study

口腔和口咽癌的甲状腺优化和甲状腺保留放射治疗:剂量学研究

阅读:1

Abstract

BACKGROUND: Radiation-induced hypothyroidism is a common toxicity of head and neck radiation. Our re-planning study aimed to reduce thyroid dose while maintaining target coverage with IMRT. METHODS: We retrospectively identified patients with oral-cavity (n = 5) and oropharyngeal cancer (n = 5). Treatment plans were re-optimized with 45 Gy thyroid mean dose constraint, then we cropped the thyroid out of PTVs and further reduced thyroid dose. Target coverage was delivering 100% dose to ≥ 93% of PTV and 95% of dose to > 99% of PTV. RESULTS: Originally, average mean dose to thyroid was 5580 cGy. In model I, this dropped to 4325 cGy (p < 0.0001). In model II, average mean dose was reduced to 3154 cGy (p < 0.0001). For PTV low and PTV int, all had acceptable target coverage. CONCLUSION: In patients with oral-cavity and oropharyngeal cancers, mean dose could be significantly reduced using a thyroid-optimized or thyroid-sparing IMRT technique with adequate coverage.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。