Ultrasensitive Detection of Severe Fever with Thrombocytopenia Syndrome Virus Based on Immunofluorescent Carbon Dots/SiO(2) Nanosphere-Based Lateral Flow Assay

基于免疫荧光碳点/SiO₂纳米球侧向流动检测法的血小板减少综合征病毒重症发热超灵敏检测

阅读:1

Abstract

Sensitive detection of severe fever with thrombocytopenia syndrome virus (SFTSV) by a point-of-care assay is of great significance for promoting clinical diagnosis. In this work, ultrasensitive detection of SFTSV was achieved by using fluorescent carbon dots/SiO(2) nanospheres (CSNs) as reporters for a lateral flow assay. The prepared CSNs were resistant to extreme environments and had strong stability. The uniform CSNs with the size of about 200 nm were obtained by differential centrifugation. Their absolute quantum yields in the aqueous and solid phases are 56.3 and 36.6%, respectively. The excellent fluorescent properties of CSNs make the test strips more sensitive and have a longer assay lifetime. Thus, the visual detection limit of the lateral flow test strip based on immunofluorescent CSN (iCSN) was as low as 10 pg/mL SFTSV nucleoprotein. The sensitivity of this assay is 2 orders of magnitude higher than that of the colloidal gold-based lateral flow test strip. Besides, the assay owns good reproducibility and high specificity. Then, iCSN-based lateral flow test strips were evaluated in real samples of human serum of patients with satisfactory results. Furthermore, this assay has a general prospect for other fluorescent immunochromatography applications.