Effect of different cross sections of polyetheretherketone splinting bars in maxillary All-on-4(®) implant supported interim prosthesis: finite element analysis study

不同截面聚醚醚酮连接杆对上颌All-on-4®种植体支持式临时修复体的影响:有限元分析研究

阅读:1

Abstract

BACKGROUND: All-on-4(®) concept allows the immediate rehabilitation of edentulous arches having anatomical limitations with provisional restoration. However, the acrylic provisional prosthesis has a critical liability to fracture, that's why a reinforcement with splinting bar is a good solution for a longer-term success. Poly Ether Ether ketone has been used as a splinting material since they are biocompatible with an elastic modulus similar to native bone and dentin with shock-absorbing characteristics. The purpose of this study was to evaluate the effect of different cross sections of Poly Ether Ether ketone splinting bars in maxillary All-on-4(®) implant supported interim prosthesis. METHODS: The current study involved two steps: virtual model construction and three-dimensional Finite Element Analysis. The virtual model composed of an edentulous maxillary cast, four dental implants placed according to the All-on-4(®)concept and an acrylic prosthetic superstructure reinforced with Poly Ether Ether ketone bar. Two virtual models were made. In the virtual model RB, a Poly Ether Ether ketone bar with rounded cross section was used. However, in the virtual model SB, a square bar was used. Each model was subjected to two types of loads: vertical load and oblique load. Each model was analyzed, and the stresses displayed in the current study are the von-Mises stress (SEqv) for the implants, marginal part of the bone cylinder, Poly Ether Ether ketone bar, prosthesis and the entire model. RESULTS: Higher stress values were observed in the model RB compared to the model SB in the implants, peri-implant bone and overlying prosthetic superstructure. However, higher stress values were recorded for the splinting bar in the model SB compared to the RB one. The highest recorded value in model RB was 120.26 MPa(*) which recorded in the prosthetic superstructure during unilateral oblique loading while the highest recorded value in model SB model was 110.51 MPa(*) which recorded in the posterior implant during unilateral oblique loading. CONCLUSION: Square cross sectioned Poly Ether Ether ketone bar induce less stress in All-On-4(®) Implant Supported Interim Prosthesis compared to the round one.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。