Precise Characterization of the Penumbra Revealed by MRI: A Modified Photothrombotic Stroke Model Study

MRI 显示的半暗影的精确表征:改良的光血栓性中风模型研究

阅读:5
作者:Cheng Qian, Pei-Cheng Li, Yun Jiao, Hong-Hong Yao, Yu-Chen Chen, Jian Yang, Jie Ding, Xiang-Yu Yang, Gao-Jun Teng

Aims

To precisely characterize the penumbra by MRI based on a modified photothrombotic stroke mouse model.

Conclusions

This study has provided a precise imaging definition of the penumbra based on a reproducible photothrombotic stroke mouse model.

Methods

The proximal middle cerebral artery was occluded by a convenient laser system in conjunction with an intravenous injection of Rose Bengal in mice. And the suture MCAO model was performed in seven mice as a comparison of the reproducibility. One hour after occlusion, the penumbra was defined in six random photothrombotic stroke mice by mismatch between perfusion-weighted imaging and the apparent diffusion coefficient map on a home-made workstation. After imaging, three random mice of them were chosen to perform the reperfusion surgery. And the other three mice were sacrificed to stain for several potential penumbra markers, such as c-fos and heart shock protein 90. In the remaining mice, the evolution of the lesions was detected on the apparent diffusion coefficient map, diffusion-weighted imaging and T2-weighted imaging at 1, 3, 6, 12 and 24 hours. After evaluating the neurological deficit scores, the brains were sectioned and stained by triphenyltetrazolium chloride and Nissl.

Results

The mice subjected to photothrombosis showed significant behavioral deficits. One hour after occlusion, the low perfusion areas on the perfusion-weighted imaging interlaced with the hypointense areas on the apparent diffusion coefficient map, demonstrating that the penumbra was located both surrounding and inside the lesions. This phenomenon was subsequently confirmed by the c-fos and heart shock protein 90 staining. The final T2-weighted images of the mice subjected to the reperfusion surgery were also consistent with the penumbra images at one hour. At early stages, the lesions were clearly identified on the apparent diffusion coefficient map; the volumes of the lesions on the diffusion-weighted imaging and T2-weighted imaging did not reach a maximum until 12 hours. The coefficient of variation (CV) of the final lesions in the photothrombotic stroke mice was 21.7% (0.08 of 0.37) on T2-weighted imaging and 27.8% (0.10 of 0.35) on triphenyltetrazolium chloride, representing a high reproducibility (n = 7). While the CV of the lesions in the MCAO stroke mice was only 70% (0.24 of 0.34, n = 4). Conclusions: This study has provided a precise imaging definition of the penumbra based on a reproducible photothrombotic stroke mouse model.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。