Difficult Preoperative Diagnosis of Suspected Metal Hypersensitivity in a Case with Early Failure of Bipolar Hemiarthroplasty

双极半髋关节置换术早期失败病例中疑似金属过敏的术前诊断困难

阅读:1

Abstract

BACKGROUND: Metal hypersensitivity is a rare complication after total hip arthroplasty (THA), and no reliable diagnostic method for metal hypersensitivity to orthopedic metal implants has yet been established. Case report. A 57-year-old woman underwent hemiarthroplasty using a metal implant despite a skin allergy to metal jewelry. Two years after surgery, the patient developed early hemiarthroplasty failure and refractory erythema. Although the patient was clinically suspected to have a hypersensitivity to metal, the preoperative screening test was negative, and patient underwent revision surgery with cemented THA. Postoperatively, the erythema as well as her hip pain disappeared completely. CONCLUSION: Patients with clinically suspected metal hypersensitivity should undergo primary and revision total hip arthroplasty using hypoallergenic implants regardless of preoperative screening results.