Characterization of Exposure to Cleaning Agents Among Health Workers in Two Southern African Tertiary Hospitals

南非两家三级医院医护人员清洁剂暴露情况特征分析

阅读:1

Abstract

BACKGROUND: Whilst cleaning agents are commonly used in workplaces and homes, health workers (HWs) are at increased risk of exposure to significantly higher concentrations used to prevent healthcare-associated infections. Exposure assessment has been challenging partly because many are used simultaneously resulting in complex airborne exposures with various chemicals requiring different sampling techniques. The main objective of this study was to characterize exposures of HWs to various cleaning agents in two tertiary academic hospitals in Southern Africa. METHODS: A cross-sectional study of HWs was conducted in two tertiary hospitals in South Africa (SAH) and Tanzania (TAH). Exposure assessment involved systematic workplace observations, interviews with key personnel, passive personal environmental sampling for aldehydes (ortho-phthalaldehyde-OPA, glutaraldehyde and formaldehyde), and biomonitoring for chlorhexidine. RESULTS: Overall, 269 samples were collected from SAH, with 62 (23%) collected from HWs that used OPA on the day of monitoring. OPA was detectable in 6 (2%) of all samples analysed, all of which were collected in the gastrointestinal unit of the SAH. Overall, department, job title, individual HW use of OPA and duration of OPA use were the important predictors of OPA exposure. Formaldehyde was detectable in 103 (38%) samples (GM = 0.0025 ppm; range: <0.0030 to 0.0270). Formaldehyde levels were below the ACGIH TLV-TWA (0.1 ppm). While individual HW use and duration of formaldehyde use were not associated with formaldehyde exposure, working in an ear, nose, and throat ward was positively associated with detectable exposures (P-value = 0.002). Glutaraldehyde was not detected in samples from the SAH. In the preliminary sampling conducted in the TAH, glutaraldehyde was detectable in 8 (73%) of the 11 samples collected (GM = 0.003 ppm; range: <0.002 to 0.028). Glutaraldehyde levels were lower than the ACGIH's TLV-Ceiling Limit of 0.05 ppm. p-chloroaniline was detectable in 13 (4%) of the 336 urine samples (GM = 0.02 ng/ml range: <1.00 to 25.80). CONCLUSION: The study concluded that detectable exposures to OPA were isolated to certain departments and were dependent on the dedicated use of OPA by the HW being monitored. In contrast, low-level formaldehyde exposures were present throughout the hospital. There is a need for more sensitive exposure assessment techniques for chlorhexidine given its widespread use in the health sector.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。