Experimental studies of thermal performance of an evacuated tube heat pipe solar collector in Polish climatic conditions

在波兰气候条件下对真空管热管太阳能集热器的热性能进行了实验研究

阅读:1

Abstract

This work presents the results of experimental studies on the energy performance of an evacuated solar collector, heat pipe type, consisting of 24 tubes, over the period of 2 months. The solar collector with a gross area of 3.9 m(2) is part the solar hot water test system located in Lublin (Poland). The effect of the weather conditions and operating parameters on the thermal and exergy efficiencies of the evacuated tube solar collector has been defined. The solar irradiation per month for July amounted to 80 kWh/m(2), and for August, it equalled 112.8 kWh/m(2). The average thermal gain was found to be in July 163 W/m(2) and in August 145 W/m(2), respectively. For the considered study period, the average value of energy yield in the solar collector was obtained at the level of 4.28 MJ/(m(2)·d). The average monthly energy efficiencies of the solar collector in July and August were 45.3% and 32.9%, respectively, while the average monthly exergy efficiencies reached 2.62% and 2.15%, respectively. Increasing the wind speed to 0.86 m/s decreases the thermal efficiency and the exergy efficiency by 67% and 41%, respectively.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。