Intraoperative Anatomical and Hemodynamic Analysis of Intracerebral Arteriovenous Malformations by Semi-quantitative Color-coded Indocyanine Green Videoangiography

术中应用半定量彩色吲哚菁绿血管造影术对脑动静脉畸形进行解剖和血流动力学分析

阅读:1

Abstract

OBJECTIVE AND BACKGROUND: To evaluate possible roles for indocyanine green (ICG)-based FLOW 800 software in surgical treatment of cerebral arteriovenous malformations (AVMs). METHODS: We perform ICG videoangiography several times for each step of AVM resection to elucidate feeders, drainers, and cerebral perfusion. RESULTS: Since 2010, 22 AVM surgeries in our department have been conducted using FLOW 800 intraoperatively. We demonstrated ICG angiograms, color-coded images, and semi-quantitative curves for AVMs. By reviewing all these modalities, we would define vascular structure of the AVM, proceed with resection, and finally recheck for any remnant. CONCLUSIONS: ICG FLOW 800 software helps the surgeon to recognize feeding and draining vessels of an AVM intraoperatively. Further studies to evaluate semi-quantitative acquired data regarding blood flow and tissue perfusion are warranted.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。