A capacitive laser-induced graphene based aptasensor for SARS-CoV-2 detection in human saliva

一种基于电容式激光诱导石墨烯的适体传感器,用于检测人类唾液中的 SARS-CoV-2

阅读:7
作者:Geisianny Moreira, Hanyu Qian, Shoumen Palit Austin Datta, Nikolay Bliznyuk, Jeremiah Carpenter, Delphine Dean, Eric McLamore, Diana Vanegas

Abstract

SARS-CoV-2 virus induced CoVID-19 pandemic has accelerated the development of diagnostic tools. Devices integrated with electrochemical biosensors may be an interesting alternative to respond to the high demand for testing, particularly in contexts where access to standard detection technologies is lacking. Aptamers as recognition elements are useful due to their stability, specificity, and sensitivity to binding target molecules. We have developed a non-invasive electrochemical aptamer-based biosensor targeting SARS-CoV-2 in human saliva. The aptamer is expected to detect the Spike protein of SARS-CoV-2 wildtype and its variants. Laser-induced graphene (LIG) electrodes coated with platinum nanoparticles were biofunctionalized with a biotin-tagged aptamer. Electrochemical Impedance Spectroscopy (EIS) for BA.1 sensing was conducted in sodium chloride/sodium bicarbonate solution supplemented with pooled saliva. To estimate sensing performance, the aptasensor was tested with contrived samples of UV-attenuated virions from 10 to 10,000 copies/ml. Selectivity was assessed by exposing the aptasensor to non-targeted viruses (hCoV-OC43, Influenza A, and RSV-A). EIS data outputs were further used to select a suitable response variable and cutoff frequency. Capacitance increases in response to the gradual loading of the attenuated BA.1. The aptasensor was sensitive and specific for BA.1 at a lower viral load (10-100 copies/ml) and was capable of discriminating between negative and positive contrived samples (with strain specificity against other viruses: OC43, Influenza A, and RSV-A). The aptasensor detected SARS-CoV-2 with an estimated LOD of 1790 copies/ml in contrived samples. In human clinical samples, the aptasensor presents an accuracy of 72%, with 75% of positive percent of agreement and 67% of negative percent of agreement. Our results show that the aptasensor is a promising candidate to detect SARS-CoV-2 during early stages of infection when virion concentrations are low, which may be useful for preventing the asymptomatic spread of CoVID-19.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。