Observational Study to Compare Biological Drug Concentration Quantification Techniques and Immunogenicity in Patients with Immune-Mediated Diseases

比较生物药物浓度定量技术和免疫介导疾病患者免疫原性的观察性研究

阅读:1

Abstract

Measuring biological drugs' trough concentrations and the concentrations of anti-drug antibodies is a valuable practice for treatment optimization. ELISA techniques are the gold standard for biological drug concentration quantification, but new techniques such as chemiluminescence immunoassays present some advantages. The aim of this unicentric prospective observational study is to compare the infliximab, adalimumab, vedolizumab and ustekinumab trough levels and anti-adalimumab and anti-infliximab antibodies concentrations obtained when using a chemiluminescent instrument (i-TRACK(®), Theradiag, Croissy-Beaubourg, France) and an ELISA instrument (TRITURUS(®), Griffols, Barcelona, Spain). Linear regression, Pearson or Spearman tests, Bland-Altman plots and the Cohen kappa test were applied for every sample. The correlation was excellent for both assays in the measurement of all drug concentrations. In general, values were lower when measured using i-TRACK than when using TRITURUS, especially when the values were high. Both techniques proved valuable in clinical practice for monitoring adalimumab and infliximab drug concentration. However, the results were modest for ustekinumab and vedolizumab, so caution is recommended and further research is needed. The limited number of anti-drug antibody-positive samples precluded a comparison between the techniques.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。