A Study on the Design of Isolator and the Mounting Method for Reducing the Pyro-Shock of a MEMS IMU

关于降低MEMS IMU热冲击的隔离器设计及安装方法的研究

阅读:1

Abstract

In this paper, we proposed two methods for reducing the pyro-shock of the MEMS Inertial Measurement Unit (IMU). First, we designed the vibration isolator for reducing the pyro-shock inside the IMU. However, it turned out that there is a limit to reducing the pyro-shock with only the vibration isolator. Therefore, we improved the pyro-shock reduction performance by changing the method of mounting on the flight vehicle. Four mounting options were tested and one of them was adopted. The results showed the best reduction performance when we designed the vibration isolator with an aluminum integrated structure. When mounting, two methods were applied. One was to insert a bracket with a different material between the mounting surface and IMU and the other was to insert a set of three washers that was stacked in a PEEK-metal-PEEK order at each part of the screw connections.