A comprehensive dosimetric study on switching from a Type-B to a Type-C dose algorithm for modern lung SBRT

对现代肺部立体定向放射治疗中从B型剂量算法切换到C型剂量算法的综合剂量学研究

阅读:1

Abstract

BACKGROUND: Type-C dose algorithms provide more accurate dosimetry for lung SBRT treatment planning. However, because current dosimetric protocols were developed based on conventional algorithms, its applicability for the new generation algorithms needs to be determined. Previous studies on this issue used small sample sizes and reached discordant conclusions. Our study assessed dose calculation of a Type-C algorithm with current dosimetric protocols in a large patient cohort, in order to demonstrate the dosimetric impacts and necessary treatment planning steps of switching from a Type-B to a Type-C dose algorithm for lung SBRT planning. METHODS: Fifty-two lung SBRT patients were included, each planned using coplanar VMAT arcs, normalized to D(95%) = prescription dose using a Type-B algorithm. These were compared against three Type-C plans: re-calculated plans (identical plan parameters), re-normalized plans (D(95%) = prescription dose), and re-optimized plans. Dosimetric endpoints were extracted and compared among the four plans, including RTOG dosimetric criteria: (R(100%), R(50%), D(2cm), V(105%), and lung V(20)), PTV D(min), D(max,) D(mean,) V(%) and D(90%), PTV coverage (V(100%)), homogeneity index (HI), and Paddick conformity index (PCI). RESULTS: Re-calculated Type-C plans resulted in decreased PTV D(min) with a mean difference of 5.2% and increased D(max) with a mean difference of 3.1%, similar or improved RTOG dose compliance, but compromised PTV coverage (mean D(95%) and V(100%) reduction of 2.5 and 8.1%, respectively). Seven plans had >5% D(95%) reduction (maximum reduction = 16.7%), and 18 plans had >5% V(100%) reduction (maximum reduction = 60.0%). Re-normalized Type-C plans restored target coverage, but yielded degraded plan conformity (average PCI reduction 4.0%), and RTOG dosimetric criteria deviation worsened in 11 plans, in R(50%), D(2cm), and R(100%). Except for one case, re-optimized Type-C plans restored RTOG compliance achieved by the original Type-B plans, resulting in similar dosimetric values but slightly higher target dose heterogeneity (mean HI increase = 13.2%). CONCLUSIONS: Type-B SBRT lung plans considerably overestimate target coverage for some patients, necessitating Type-C re-normalization or re-optimization. Current RTOG dosimetric criteria appear to remain appropriate.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。