Experience of treating congenital complete atrioventricular block with epicardial pacemaker in infants and young children: a retrospective study

婴儿和幼儿先天性完全性房室传导阻滞植入心外膜起搏器治疗经验:一项回顾性研究

阅读:1

Abstract

BACKGROUND: This article summarizes the treatment experience for congenital complete atrioventricular block (CCAVB) in newborns and infants, and discusses the necessity and feasibility of treating CCAVB with permanent pacemaker implantation in this population. METHODS: In this study, the clinical data and follow-up results of nine children admitted at our center with CCAVB from January 2005 to March 2023 were retrospectively analyzed. Among them, two children received early implantation of permanent pacemakers (within 1 year of age), two children received non-early implantation (1 year or older), and the remaining five children received no pacemaker implantation. CCAVB diagnosis was confirmed by clinical symptoms and clinical examinations, including electrocardiography and echocardiography before surgery. After surgery, the pacing and sensing functions of the pacemaker were observed using electrocardiography, echocardiography, and pacing threshold monitoring. A comprehensive assessment of the treatment efficacy was conducted, encompassing improvements in clinical symptoms, growth and development, as well as the absence of any additional potential complications. The children who did not receive pacemaker implantation were followed up. RESULTS: Among the four children who successfully received pacemaker implantation, one child who received non-early implantation died. For the remaining three children, the threshold level, amplitude, impedance, and minute ventilation sensor function of the pacemaker were good during the follow-up period, with a heart rate at the pacing rate. The growth and development of the aforementioned patients who received pacemaker implantation demonstrated adherence to the percentile curve, and their motor and cognitive development remained unaffected. However, among the children who did not undergo pacemaker implantation, two experienced death, while three were lost to follow-up, thereby limiting the evaluation of their long-term outcomes. CONCLUSIONS: Early implantation of an epicardial pacemaker at an early stage in newborns and infants diagnosed with CCAVB can significantly improve clinical symptoms without affecting their growth and development. These data are in line with current literature and suggest that early implantation of an epicardial pacemaker in newborns and infants diagnosed with CCAVB but further studies are needed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。