Development of Optical Nanosensors for Detection of Potassium Ions and Assessment of Their Biocompatibility with Corneal Epithelial Cells

用于检测钾离子的光学纳米传感器的开发及其与角膜上皮细胞的生物相容性的评估

阅读:5
作者:Hannah M Dewey, Nasif Mahmood, Sofia Mariapaz Abello, Nigar Sultana, Jaron Jones, Jessica M Gluck, Januka Budhathoki-Uprety

Abstract

Imbalance of potassium-ion levels in the body can lead to physiological dysfunctions, which can adversely impact cardiovascular, neurological, and ocular health. Thus, quantitative measurement of potassium ions in a biological system is crucial for personal health monitoring. Nanomaterials can be used to aid in disease diagnosis and monitoring therapies. Optical detection technologies along with molecular probes emitting within the near-infrared (NIR) spectral range are advantageous for biological measurements due to minimal interference from light scattering and autofluorescence within this spectral window. Herein, we report the development of NIR fluorescent nanosensors, which can quantitatively detect potassium ions under biologically relevant conditions. The optical nanosensors were developed by using photoluminescent single-walled carbon nanotubes (SWCNTs) encapsulated in polymers that contain potassium chelating moieties. The nanosensors, polystyrene sulfonate [PSS-SWCNTs, nanosensor 1 (NS1)] or polystyrene-co-polystyrene sulfonate [PS-co-PSS-SWCNTs, nanosensor 2 (NS2)], exhibited dose-dependent optical responses to potassium ion level. The nanosensors demonstrated their biocompatibility via the evaluation of cellular viability, proliferation assays, and expression of cytokeratin 12 in corneal epithelial cells (CEpiCs). Interestingly, the nanosensors' optical characteristics and their responses toward CEpiCs were influenced by encapsulating polymers. NS2 exhibited a 10 times higher fluorescence intensity along with a higher signal-to-noise ratio as compared to NS1. NS2 showed an optical response to potassium ion level in solution within 5 min of addition and a limit of detection of 0.39 mM. Thus, NS2 was used for detailed investigations including potassium ion level detection in serum. NS2 showed a consistent response to potassium ions at the lower millimolar range in serum. These results on optical sensing along with biocompatibility show a great potential for nanotube sensors in biomedical research.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。